group Experiment-specific electron efficiency and smearing functions
Experiment-specific electron efficiency and smearing functions
Module: Detector smearing & efficiency functions
Functions
Name | |
---|---|
double | ELECTRON_RECOEFF_ATLAS_RUN1(const Particle & e) |
double | ELECTRON_RECOEFF_ATLAS_RUN2(const Particle & e) |
double | ELECTRON_EFF_ATLAS_RUN2_LOOSE(const Particle & e) ATLASRun 2 ’loose’ electron reco+identification efficiency. |
double | ELECTRON_EFF_ATLAS_RUN1_MEDIUM(const Particle & e) ATLASRun 1 ‘medium’ electron reco+identification efficiency. |
double | ELECTRON_EFF_ATLAS_RUN2_MEDIUM(const Particle & e) ATLASRun 2 ‘medium’ electron reco+identification efficiency. |
double | ELECTRON_EFF_ATLAS_RUN1_TIGHT(const Particle & e) ATLASRun 1 ’tight’ electron reco+identification efficiency. |
double | ELECTRON_EFF_ATLAS_RUN2_TIGHT(const Particle & e) ATLASRun 2 ’tight’ electron reco+identification efficiency. |
Particle | ELECTRON_SMEAR_ATLAS_RUN1(const Particle & e) ATLASRun 1 electron reco smearing. |
Particle | ELECTRON_SMEAR_ATLAS_RUN2(const Particle & e) |
double | ELECTRON_EFF_CMS_RUN1(const Particle & e) CMS Run 1 electron reconstruction efficiency. |
double | ELECTRON_EFF_CMS_RUN2(const Particle & e) |
Particle | ELECTRON_SMEAR_CMS_RUN1(const Particle & e) CMS electron energy smearing, preserving direction. |
Particle | ELECTRON_SMEAR_CMS_RUN2(const Particle & e) |
Functions Documentation
function ELECTRON_RECOEFF_ATLAS_RUN1
inline double ELECTRON_RECOEFF_ATLAS_RUN1(
const Particle & e
)
Todo: Include reco eff (but no e/y discrimination) in forward region
ATLASRun 1 electron reconstruction efficiency
function ELECTRON_RECOEFF_ATLAS_RUN2
inline double ELECTRON_RECOEFF_ATLAS_RUN2(
const Particle & e
)
ATLASRun 2 electron reco efficiency
Based on https://arxiv.org/pdf/1902.04655.pdf Fig 2
function ELECTRON_EFF_ATLAS_RUN2_LOOSE
inline double ELECTRON_EFF_ATLAS_RUN2_LOOSE(
const Particle & e
)
ATLASRun 2 ’loose’ electron reco+identification efficiency.
Todo: What about faking by jets or non-electrons?
Values read from Fig 3 of ATL-PHYS-PUB-2015-041
function ELECTRON_EFF_ATLAS_RUN1_MEDIUM
inline double ELECTRON_EFF_ATLAS_RUN1_MEDIUM(
const Particle & e
)
ATLASRun 1 ‘medium’ electron reco+identification efficiency.
function ELECTRON_EFF_ATLAS_RUN2_MEDIUM
inline double ELECTRON_EFF_ATLAS_RUN2_MEDIUM(
const Particle & e
)
ATLASRun 2 ‘medium’ electron reco+identification efficiency.
~1% increase over Run 1 informed by Fig 1 in https://cds.cern.ch/record/2157687/files/ATLAS-CONF-2016-024.pdf
function ELECTRON_EFF_ATLAS_RUN1_TIGHT
inline double ELECTRON_EFF_ATLAS_RUN1_TIGHT(
const Particle & e
)
ATLASRun 1 ’tight’ electron reco+identification efficiency.
function ELECTRON_EFF_ATLAS_RUN2_TIGHT
inline double ELECTRON_EFF_ATLAS_RUN2_TIGHT(
const Particle & e
)
ATLASRun 2 ’tight’ electron reco+identification efficiency.
~1% increase over Run 1 informed by Fig 1 in https://cds.cern.ch/record/2157687/files/ATLAS-CONF-2016-024.pdf
function ELECTRON_SMEAR_ATLAS_RUN1
inline Particle ELECTRON_SMEAR_ATLAS_RUN1(
const Particle & e
)
ATLASRun 1 electron reco smearing.
function ELECTRON_SMEAR_ATLAS_RUN2
inline Particle ELECTRON_SMEAR_ATLAS_RUN2(
const Particle & e
)
Todo: Currently just a copy of the Run 1 version: fix!
ATLASRun 2 electron reco smearing
function ELECTRON_EFF_CMS_RUN1
inline double ELECTRON_EFF_CMS_RUN1(
const Particle & e
)
CMS Run 1 electron reconstruction efficiency.
Todo: Add charge flip efficiency?
function ELECTRON_EFF_CMS_RUN2
inline double ELECTRON_EFF_CMS_RUN2(
const Particle & e
)
Todo: Currently just a copy of Run 1: fix!
CMS Run 2 electron reco efficiency
function ELECTRON_SMEAR_CMS_RUN1
inline Particle ELECTRON_SMEAR_CMS_RUN1(
const Particle & e
)
CMS electron energy smearing, preserving direction.
Calculate resolution for pT > 0.1 GeV, E resolution = |eta| < 0.5 -> sqrt(0.06^2 + pt^2 * 1.3e-3^2) |eta| < 1.5 -> sqrt(0.10^2 + pt^2 * 1.7e-3^2) |eta| < 2.5 -> sqrt(0.25^2 + pt^2 * 3.1e-3^2)
function ELECTRON_SMEAR_CMS_RUN2
inline Particle ELECTRON_SMEAR_CMS_RUN2(
const Particle & e
)
Todo: Currently just a copy of the Run 1 version: fix!
CMS Run 2 electron reco smearing
Updated on 2022-08-07 at 20:17:18 +0100